2026-08-16: SMART disk health, and onboarding the hypervisor

Adding disk health turned out to require onboarding a host that had been deliberately excluded, because nothing already monitored can report SMART.

Why the fleet could not answer

Probed before designing anything, which is what changed the plan:

Platform Hosts Result
LXC tailscale-router, plex, memory, monitor-lxc disks visible in /sys (so lsblk lists them) but no /dev nodes
KVM ubuntu-dev, ubuntu-ai, cloud-services, matrix device lacks SMART capability on the QEMU virtual disk
Pi rpi5, rpi4b type=SD; SD does not implement SMART, and eMMC fields are absent

The LXC case is the trap: lsblk inside those containers lists the real Seagate and Samsung drives, so it looks like SMART should work. It cannot; smartctl reports No such device because the device nodes do not exist in the container.

The only real disks belong to t7920, the Proxmox host, which was out of inventory by an earlier explicit decision. Onboarded as a fourth platform group, metal, and deliberately kept out of autoupdate: an unattended upgrade there restarts pveproxy/pvedaemon underneath every running guest.

ansible-inventory --host t7920      # monitor_role=hypervisor, smart_metrics_enabled=True
ansible autoupdate --list-hosts     # t7920 absent, as intended

ansible-playbook playbooks/collectors.yml     --limit t7920
ansible-playbook playbooks/update-metrics.yml --limit t7920

--check cannot work against a brand-new host

The first dry run failed with No package matching 'alloy' is available. That is a check-mode artifact, not a fault: check mode does not really add the Grafana APT repository, so the package genuinely is not visible yet. Verified by confirming no repo file existed, then ran for real.

What it found immediately

/dev/sda     ST2000DM005-2U9102   18077 power-on hours, 33 C
             reallocated=0  pending=0  offline_uncorrectable=0  CRC=23
/dev/nvme0   PM9A1 NVMe 1TB       20180 power-on hours, 35 C
             life used=23%  spare=100%  media errors=0  unsafe shutdowns=266

Both healthy. The 23 CRC errors are a past SATA link event, not a failing platter, and 266 unsafe shutdowns is worth knowing on a hypervisor.

A false "we are patched" signal, exposed by the new host

fleet_unattended_upgrades_enabled reported 1 for t7920, a box where unattended-upgrade is not even installed. The exporter tested only apt-daily-upgrade.timer, which ships enabled on stock Debian.

This was invisible while every monitored host was in autoupdate, since both halves were true there. It applies equally to the no_autoupdate group, whose 20auto-upgrades sets Unattended-Upgrade "0" while leaving the timer on. That group is empty today, which is why it had never surfaced.

The metric now requires the timer and an effective APT::Periodic::Unattended-Upgrade "1" and the binary to exist, and fleet-security-updates-stuck is gated on it, so it no longer fires on a hand-patched host with a runbook naming a binary that is not installed.

ansible-playbook playbooks/update-metrics.yml     # corrected exporter, fleet-wide
ansible-playbook playbooks/central-alerting.yml   # rules-storage + gated rules-updates
# t7920 now correctly reports enabled=0; the other ten still report 1

Verification

  • 29 unique PromQL expressions across the t7920 dashboard and the 8 new storage rules: all parse and all return data against live Prometheus.
  • 8 storage alerts live, all inactive. Notably fleet-smart-crc-errors-rising is inactive despite the existing 23 errors, which is the whole point of alerting on increase() rather than > 0.
  • Fleet-wide: 32 inactive, 1 firing (rpi5 systemd unit, pre-existing), 1 pending (main-server security updates, genuine and pre-existing).

Still outstanding

rpi5 has a failed systemd unit that predates this work and is still firing.


2026-08-15: per-host dashboards and GPU telemetry

Three changes in one rollout:

  1. Per-host dashboards. One dedicated dashboard per host in a new Servers Grafana folder, alongside the existing fleet-wide Monitoring folder.
  2. GPU telemetry on ubuntu-ai. The nvtop figures (utilization, VRAM, temperature, power, fan) via a new gpu_exporter role.
  3. Silenced fleet-load-high for tailscale-router, which was firing permanently.

Phase 0: preflight

Every host was unreachable on the first attempt except tailscale-router:

cd ansible
ansible monitored -m ping
# 9 of 10 UNREACHABLE, "Operation timed out"

This was not an outage. Tailscale reported every peer active, and nc -z <ip> 22 succeeded on all of them. The paths were cold DERP relays and Ansible's default 10-second timeout expired during path setup. Raising the timeout fixed it permanently:

ANSIBLE_TIMEOUT=30 ansible monitored -m ping     # 10/10 SUCCESS

ANSIBLE_TIMEOUT=30 for any tailnet-wide play

Every command in this rollout used it. Without it the first play of the day fails on hosts that are perfectly healthy, which is an expensive way to learn that a relay took eleven seconds to come up.

Two facts were confirmed against the hosts before anything was written, because both were assumptions the work depended on:

ansible monitor-lxc -m shell -a 'grep MONITOR_HOSTNAME /etc/default/alloy'
#   MONITOR_HOSTNAME="main-server"   <- NOT "monitor-lxc"

ansible ubuntu-ai -m shell -a 'nvidia-smi --query-gpu=name,driver_version --format=csv,noheader'
#   NVIDIA RTX A5000, 595.84

The first is why servers/monitor-lxc.json queries host="main-server" throughout. Had it been taken on trust, all 16 of its panels would have been permanently blank. See Dashboards.

Phase 1: the central LXC was 100% full

The fleet-wide dry run failed on monitor-lxc only:

ansible-playbook playbooks/collectors.yml --check --diff
#   monitor-lxc : failed=1
#   E:Write error - write (28: No space left on device)

/ was 7.4G of 7.8G used, 0 bytes available, with /var/lib/prometheus at 3.1G. All five services still reported active, which is exactly why this had gone unnoticed: nothing crashes, writes just start failing.

Cleared with the two cheapest steps from the disk runbook, neither of which discards monitoring data:

ansible monitor-lxc -m shell -a 'apt-get clean; journalctl --vacuum-size=64M'
#   100% used, 0 avail  ->  97% used, 234M avail

Freeing 234M eventually returned 2.1G

By the end of the rollout / was at 72% used, 2.1G available. Nothing else was deleted. Prometheus had been unable to complete a compaction with zero bytes free; given headroom it finished and dropped the old blocks. A full disk on the central node is therefore self-reinforcing, and worth breaking early.

Phase 2: collectors, in blast-radius order

The dry run also confirmed GPU autodetection fleet-wide before any host was touched: gpu=True on ubuntu-ai alone, gpu=False on the other nine.

ansible-playbook playbooks/collectors.yml --limit ubuntu-dev          # canary
ansible-playbook playbooks/collectors.yml --limit ubuntu-ai           # the GPU host
ansible-playbook playbooks/collectors.yml --limit 'cloud-services,rpi5,rpi4b'
ansible-playbook playbooks/collectors.yml --limit lan_guests          # plex, memory, matrix
ansible-playbook playbooks/collectors.yml --limit tailscale-router    # exit node
ansible-playbook playbooks/collectors.yml --limit monitor-lxc         # LAST
Host changed Note
ubuntu-dev 0 canary; config renders byte-identical on a non-GPU host
ubuntu-ai 9 exporter installed, Alloy gained the GPU scrape block
cloud-services, rpi5, rpi4b 1 each
plex, matrix 0
memory 1
tailscale-router 0
monitor-lxc 1

changed=0 on the canary is the important number: it proves the template change is inert on hosts without a GPU, so nine machines got no Alloy restart.

Phase 3: Grafana

Dashboards are not handled by any role, so they go by the copy path documented in Dashboards. The two provider directories must be disjoint, because Grafana scans each provider path recursively:

ansible monitor-lxc -m file -a 'path=/var/lib/grafana/dashboards/fleet   state=directory owner=grafana group=grafana mode=0755'
ansible monitor-lxc -m file -a 'path=/var/lib/grafana/dashboards/servers state=directory owner=grafana group=grafana mode=0755'

ansible monitor-lxc -m copy -a 'src=../grafana/dashboards/fleet/   dest=/var/lib/grafana/dashboards/fleet/   owner=grafana group=grafana mode=0644'
ansible monitor-lxc -m copy -a 'src=../grafana/dashboards/servers/ dest=/var/lib/grafana/dashboards/servers/ owner=grafana group=grafana mode=0644'
ansible monitor-lxc -m copy -a 'src=../grafana/provisioning/dashboards/dashboards.yml dest=/etc/grafana/provisioning/dashboards/dashboards.yml owner=root group=grafana mode=0644'

The three fleet dashboards moved from the root of the tree into fleet/, so the old copies at the root were removed. No provider reads that path any more, but leaving them invites a future reader to edit a file nothing loads:

for f in services-monitoring.json system-overview.json vm-fleet-overview.json; do
  ansible monitor-lxc -m file -a "path=/var/lib/grafana/dashboards/$f state=absent"
done

The alert rule change is a different mechanism: rules-resources.yaml is one of grafana_alerting_static_files, so it ships with the role, which also restarts Grafana. Running it last meant a single restart picked up both the new provider config and the new rule:

ansible-playbook playbooks/central-alerting.yml    # changed=2

Phase 4: verification

Against the live stack, not the repo:

# 13 dashboards, correctly split, no duplicate-provisioning errors
curl -s -u "$AUTH" 'http://127.0.0.1:3000/api/search?type=dash-db&limit=100'
#   Monitoring [3], Servers [10]

# GPU metrics arriving in CENTRAL Prometheus, labelled host=ubuntu-ai
curl -s http://127.0.0.1:9090/api/v1/query --data-urlencode 'query=nvidia_smi_temperature_gpu'

# the load alert now evaluates 9 hosts, not 10
curl -s http://127.0.0.1:9090/api/v1/query --data-urlencode \
  'query=max by (host) (node_load15{host!="tailscale-router"}) / on (host) count by (host) (count by (host, cpu) (node_cpu_seconds_total{mode="idle",host!="tailscale-router"}))'

Results:

  • 13 dashboards: 3 in Monitoring, 10 in Servers, zero provisioning errors.
  • GPU: all five nvidia_smi_* families present with host="ubuntu-ai". Observed mid-rollout at 22.2 GB VRAM / 55 °C under load, and 454 MB / 33 °C after it finished, so the panels were confirmed against both states.
  • Per-host dashboards: the primary CPU query returned data on all ten, main-server included.
  • Load alert: 9 hosts evaluated, tailscale-router absent. Its real value is 2.5 load/core against a threshold of 2, so it had been firing continuously; the next-highest host in the fleet is 1.25.
  • Fleet: alloy active on all 10; grafana-server, prometheus, loki, alloy, nginx all active centrally.

Still outstanding

/var/lib/prometheus is 3.1G on a 7.8G disk. The 72% figure above is healthy today, but nothing about the rollout changed retention, and the incident in Phase 1 will recur as the TSDB grows. The durable fix is a retention decision, not a cleanup: see Retention.